Thermis Log 10TH USB Temp & Humidity Logger

Data Loggers
Thermis Log USB data logger with an LCD screen
Thermis Log 10TH USB Temp & Humidity Logger

Two channels for the recording task

See the conditions locally. Keep the completed record.

A configurable, single-use temperature and humidity logger with an LCD display, event marks, and automatic USB reports for sensitive storage and transport tasks.

Thermis Log 10TH records temperature and humidity during a defined storage or transport task. Its LCD screen provides local readings and status, while the USB connection makes the report available to the team reviewing the completed record.

The recording parameters are configurable before start, allowing the interval, delays, and alarm settings to reflect the task. The 10TH model includes humidity sensing; the separate Thermis Log 10T is temperature-only. Confirm the exact supplied model and recording duration when selecting a unit.

Enquire about this product
  • Temperature + RH10TH measurement channels
  • Single-useConfigurable before start
  • LCD & USBLocal status and report access

Configured for the application

A local display and a record for review.

Select the parameters around the product requirements and the way the record will be assessed.

  • Temperature and humidity channels

    The 10TH model captures both measurements, with LCD readings and alarm status available at the device.

  • Pre-start configuration

    Set supported recording parameters before starting the single-use task, including the interval, delay, and alarm points.

  • Marks and temporary reports

    Use the supported event-mark function to identify key moments. A temporary report mode is available for an interim review.

  • Automatic USB reports

    Obtain PDF and CSV report options through direct USB connection without export software. Confirm the selected report format and supplied documentation.

Technical details

Details for the 10TH model.

Manufacturer information for Thermis Log 10TH. Confirm the supplied version, duration, and configuration for the task.

Use type
Single-use
Measurements
Temperature and relative humidity
Temperature range
−30°C to +70°C
Temperature accuracy
±0.3°C over the full range
Humidity range
0–100% RH
Humidity accuracy
±3% RH at 25°C, 20–80% RH; ±5% RH elsewhere
Display
LCD and LED
Maximum alarm points
Six
Maximum event marks
Nine
Connection
USB
Protection
IP65
Dimensions
94 × 41 × 8 mm

Prepare the single-use task

Configure. Start. Retrieve.

Use the operating instructions and configuration tools supplied for the selected version.

  1. Set the parameters

    Confirm the 10TH model and configure the supported interval, delay, alarm, and report settings before the task starts.

  2. Start and place

    Start the logger using its instructions and place it at the defined location. Use the screen to review running status and the supported mark function when needed.

  3. Review the report

    Use the temporary-report procedure for an interim check, or stop the task as instructed and connect by USB for the final report. Retain the files with your monitoring records.

Sensitive storage and transport

Record both channels for the review ahead.

Assess suitability against the product conditions, required interval, and expected recording period.

  • Insulated cold-room doors along a refrigerated warehouse corridor

    Pharmaceutical distribution

    Document temperature and humidity for a defined consignment, using settings chosen for the goods and their handling requirements.

  • Temperature probes arranged across the shelves of a laboratory calibration chamber

    Laboratory storage tasks

    Collect a two-channel environmental record around sensitive materials for review alongside the laboratory’s storage requirements.

  • Insulated cold room with refrigeration equipment and storage shelving

    Refrigerated storage

    Use the local display and completed report to review the conditions in a specified cabinet, cooler, or storage area.

Product enquiries

Set up the two-channel record you need.

Share the required temperature and humidity conditions, task duration, interval, alarm settings, and report requirements. Celsius can discuss the supplied version and configuration.

Enquire about this product
How does Thermis Log 10TH differ from 10T?

The 10TH records temperature and humidity. The 10T is temperature-only. Choose the model according to the measurements needed for the product and recording task.

Is Thermis Log 10TH reusable after downloading the report?

No. Thermis Log 10TH is a single-use logger. A temporary report is available through the supported procedure during the task, but the device should not be selected as a reusable logger for successive trips.

Plan your environmental control

Start with your requirements.

Share your facility, product, and temperature or humidity requirements. We can help define the refrigeration, qualification, and monitoring support you need.