TagPlus / TagPlus-TH Series

Data Loggers
Freshliance TagPlus USB temperature data logger with an LCD screen
TagPlus / TagPlus-TH Series

Reusable recording with a local display

Choose the channels. Keep the trip history.

Reusable USB loggers with configurable alarms, LCD status, and report access: TagPlus-T records temperature, while TagPlus-TH adds humidity.

TagPlus-T and TagPlus-TH provide configurable recording for storage and transport tasks. TagPlus-T measures temperature; TagPlus-TH records both temperature and humidity. Their LCD screens provide a local view of readings and status while the record is being collected.

Use the configuration tools to set the supported interval, delay, and alarm parameters before a task. Reports are generated through the USB connection, and the temporary-report mode supports an interim review. Retain the completed record before preparing a unit for reuse.

Enquire about this product
  • ReusableUSB data loggers
  • T or THSelect the measured parameters
  • LCDLocal readings and status

Control the recording task

Settings and reports for repeated use.

Select the sensor variant and report mode that match the information you need to record.

  • Temperature or combined sensing

    Choose TagPlus-T for temperature recording or TagPlus-TH where humidity readings are also required.

  • Configurable alarms and events

    Supported settings include up to six alarm points and nine event marks, providing a way to relate selected events to the record.

  • LCD status and statistics

    The screen displays current readings, alarm status, and trip statistics for local review.

  • USB and temporary reports

    Generate reports on a computer without export software. Use the supported temporary-report mode to review an ongoing record.

Model and report options

Specify T or TH before setting the task.

Shared features and model differences from the manufacturer. Confirm the supplied range option and report configuration.

TagPlus-T measurement
Temperature
TagPlus-TH measurement
Temperature and relative humidity
Standard temperature range
−30°C to +70°C
Optional temperature range
−40°C to +60°C; confirm supplied model
Temperature accuracy
±0.5°C over the specified range
TagPlus-TH humidity range
0–100% RH
TagPlus-TH humidity accuracy
±3% RH at 25°C, 20–80% RH; ±5% RH elsewhere
Logging interval
1 minute to 24 hours; configurable
Report options
PDF, CSV, or PDF and CSV
Memory by report mode
PDF: up to 35,000 readings; combined PDF and CSV: up to 20,000 readings each
Battery
Replaceable 3.0 V CR2032
Protection
IP65

A repeatable recording routine

Prepare. Record. Retain.

Use the configuration and operating instructions for the selected model.

  1. Prepare the logger

    Confirm the T or TH model, battery status, report mode, and recording parameters. Retain any previous report before preparing a new task.

  2. Start and place

    Start the configured task using the supported controls and place the logger at the defined location. Review its LCD status as required.

  3. Retrieve and save

    End the task using the instructed procedure and connect by USB to obtain the report. Save the files before preparing the logger for reuse.

Repeated storage and transport tasks

Keep a record for each defined use.

Match the channels and configuration to the product requirements and monitoring procedure.

  • Two inspectors in safety equipment checking refrigerated shipping containers

    Food and produce logistics

    Record temperature, and humidity where required, around perishable goods during a defined storage or transport task.

  • Insulated cold room with refrigeration equipment and storage shelving

    Controlled storage areas

    Use the local display for operator checks and retain the completed record to review conditions in the selected space.

  • Worker checking palletized goods with a handheld scanner in a cold-storage warehouse

    Receiving and distribution

    Relate event marks and the completed report to handling activities, with the appropriate T or TH model selected before use.

Product enquiries

Choose the channels and recording settings.

Share the required measurements, range, interval, expected task duration, and report needs. Celsius can discuss the appropriate TagPlus model and configuration.

Enquire about this product
Does every TagPlus logger record humidity?

No. TagPlus-T is the temperature-only model. TagPlus-TH adds relative humidity measurement. Confirm the required channels and the exact range option when selecting the unit.

Can I review a report before the task has finished?

The manufacturer provides a temporary-report mode that allows recording to continue after an interim report is obtained. Follow that procedure when an ongoing record is required, and retain the final report before preparing the unit for reuse.

Plan your environmental control

Start with your requirements.

Share your facility, product, and temperature or humidity requirements. We can help define the refrigeration, qualification, and monitoring support you need.